Model TP is the third generation single-stage circulation water pump designed for maximum 140ºC water and industrial fluids. Compared with the previous generation, the efficiency of the series is increased by 5% on average and TP has been the national energy-saving product certificated. The series have horizontal and vertical structures to meet different installation requirement. To achieve world-class quality, pump body and impeller are mechanically molded with coated sand, machined with four-axis CNC machining center and finished with electrophoresis. Big pump offer push-pull base for easy maintenance besides standard base
Type | Capacity | Head | Speed | Eff. | Shaft Power | Motor Power | (NPSH)r | Weight | |
Q | H | n | η | Pa | PM | ||||
(m3/h) | (L/s) | (m) | (r/min) | (%) | (kW) | (kW) | (m) | (kg) | |
40TP(L)15-1.1/2 | 11.2 | 3.1 | 16 | 2960 | 59 | 0.83 | 1.1 | 1.8 | 45 |
13.6 | 3.8 | 15.5 | 63 | 0.91 | 1.8 | ||||
16 | 4.4 | 15 | 66 | 0.99 | 1.8 | ||||
17.6 | 4.9 | 13.6 | 65 | 1.00 | 1.8 | ||||
19.2 | 5.3 | 12.3 | 64 | 1.01 | 1.9 | ||||
40TP(L)19-1.5/2 | 12.6 | 3.5 | 20.9 | 61 | 1.18 | 1.5 | 1.8 | 48 | |
15.3 | 4.3 | 20 | 65 | 1.28 | 1.8 | ||||
18 | 5 | 19 | 67 | 1.39 | 1.8 | ||||
19.8 | 5.5 | 18.1 | 67.1 | 1.46 | 1.9 | ||||
12.6 | 3.5 | 20.9 | 66.8 | 1.50 | 2.5 | ||||
40TP(L)23-2.2/2 | 14 | 3.9 | 25.4 | 62 | 1.56 | 2.2 | 1.6 | 52 | |
17 | 4.7 | 24.6 | 65 | 1.75 | 1.8 | ||||
20 | 5.6 | 23 | 68 | 1.84 | 2 | ||||
22 | 6.1 | 22.3 | 68 | 1.97 | 2.6 | ||||
24 | 6.7 | 21.2 | 67.4 | 2.06 | 2.8 | ||||
40TP(L)28-3/2 | 15.4 | 4.3 | 31 | 2960 | 54 | 2.41 | 3 | 1.8 | 65 |
18.7 | 5.2 | 30 | 58 | 2.64 | 1.9 | ||||
22 | 6.1 | 28 | 61 | 2.75 | 2.2 | ||||
24.2 | 6.7 | 27.2 | 61 | 2.94 | 2.7 | ||||
26.4 | 7.3 | 26.5 | 62 | 3.08 | 3 | ||||
40TP(L)34-4/2 | 17.5 | 4.9 | 36.2 | 55 | 3.14 | 4 | 1.8 | 72 | |
21.3 | 5.9 | 35.1 | 59 | 3.45 | 2 | ||||
25 | 6.9 | 34 | 62 | 3.74 | 2.8 | ||||
27.5 | 7.6 | 33 | 63.5 | 3.89 | 3.1 | ||||
30 | 8.3 | 31.8 | 63.3 | 4.11 | 3.5 | ||||
40TP(L)37-5.5/2 | 21 | 5.8 | 41 | 2960 | 54 | 4.35 | 5.5 | 2.1 | 110 |
25.5 | 7.1 | 39.2 | 58 | 4.70 | 2.8 | ||||
30 | 8.3 | 37 | 61 | 4.96 | 4 | ||||
33 | 9.2 | 36 | 60.6 | 5.34 | 5.3 | ||||
36 | 10 | 33.4 | 59.4 | 5.52 | 6 | ||||
40TP(L)43-7.5/2 | 24.5 | 6.8 | 49 | 56 | 5.49 | 7.5 | 2.7 | 116 | |
30 | 8.3 | 47 | 59 | 6.08 | 3.6 | ||||
35 | 9.7 | 43 | 62 | 6.38 | 5.2 | ||||
38.5 | 10.7 | 41.3 | 60 | 6.79 | 6 | ||||
42 | 11.7 | 39.4 | 59 | 7.32 | 7.3 |
Attribute | Attributes | Value | Optional |
Installation | Inlet Diameter (mm) | DN40 | |
Outlet Diameter (mm) | DN40 | ||
Direction of rotation | Clockwise from the motor to the pump | ||
Entrance orientation | level in | ||
Exit orientation | level out | ||
Base form | |||
Motor | Number of motor phases | 3 | |
Rated voltage (V) | 380 | ||
Power frequency (Hz) | 50 | 60 | |
Insulation class | F | ||
Protection class | IP54 | ip55 | |
Cooling Method | Air-cooled | ||
Energy efficiency rating | IE3 | IE4/IE5 |